Laboratory of Non Destructive Testing
Laboratory of Non Destructive Testing
Air Force Institute of Technology
|
Primary lines of activity:
-
Detection of hidden corrosion
-
Detection of fatigue cracks
-
Detection of delamination (composite structures)
-
Detection of disbonds (in complex structures, e.g. composite/ metal, honeycomb elements)
-
Detection of porosity (composite structures)Finding inclusions of foreign objects (composite
structures)
-
Detections of disbonds (honeycomb elements)
-
Cracks inspection in riveted, bolted, welded,
and bonded joints
-
Detection of pitting corrosion
-
Water inclusions inspection in honeycomb
structures
-
Development of research/testing methods and
procedures
-
Thickness measurements
-
Determination of conductivity of materials (according to IACS standard)
Research/Testing methods in use:
-
Automatic PC interface supported and manual
methods
-
Eddy current inspection
-
Ultrasonic inspection
-
Acoustic low-frequency inspection (MIA, Pitch-Catch, Resonance)
-
D-Sight inspection
-
Shearography
-
Penetrant inspection
-
Magnetic particle inspection
-
Visual inspection
Capabilities:
-
Staff certified according to requirements of the DGZfP, UDT-CERT, and
BINDT
-
Laboratory has been granted the second- and third-rate certificates
More: www.itwl.pl/badania/
|
CONTACTS:
|
Air
Force Institute of Technology
Laboratory of Non Destructive Testing
ul. Ksiecia Boleslawa 6
01-494 Warszawa POLAND
|
Head of laboratory:
Krzysztof DRAGAN
tel. + 48 22 685 19 65;
fax + 48 22 685 21 63
mobile phone: +48 602 730 652
e-mail: krzysztof.dragan@itwl.pl
|
|
Thanks to all who contributed to that presentaion of NDT in Poland, especially sponsors
sincerely, Gracjan Wisniewski, president of PTBNiDT
Main sponsor:
Reminder sponsors:

 CLDT










Zawada
NDT

|